Uploaded image for project: 'Instrument control development'
  1. Instrument control development
  2. INSTRM-1028

(re-)Add BEE-side ADIO mask to gatevalve keyword

    XMLWordPrintable

    Details

    • Story Points:
      1

      Description

      When we switched to the new interlock board the old gatevalve status key was changed from being generated entirely from the BEE's ADIO I/O mask to being regenerated from the interlock board status command output. Given that we lost access to most of the hardware signals and gained other info from the interlock board that made sense.

      But there was one ADIO signal we should have kept reporting: the one which the xcuActor asserts or clears to actually request that the valve be opened or closed. When that is written to it reads back as the last-written value, which can be a comforting thing to know.

      I'll prepend the entire 8-bit ADIO word to the current interlock-derived 8 bits. The other seven bits should not change, but they could prove informative.

        Attachments

          Issue Links

            Activity

              People

              • Assignee:
                cloomis cloomis
                Reporter:
                cloomis cloomis
              • Votes:
                0 Vote for this issue
                Watchers:
                1 Start watching this issue

                Dates

                • Created:
                  Updated:
                  Resolved: