Type: Task
-
Status: Done (View Workflow)
-
Priority: Normal
-
Resolution: Done
-
Affects Version/s: None
-
Fix Version/s: None
-
Component/s: None
-
Labels:None
-
Story Points:3
-
Sprint:2DDRP-2021 A11
(This ticket is a consequence of an attempt to do finer granulation of PIPE2D-928).
I am noticing problems in my creation of variance images. At the moment I am creating ``custom'' variance images which are created from the model images. To get the relation between the values in the variance and science images I do a simple 2nd order fit and apply this relation to the model image to get the variance image. The mistake I have made is that I am reusing the previous variance image (instead of the original variance image) to create a new variance image. This leads to runaway values in the variance image and eventually to the crash.
I have only noticed this now as I have modified the 2nd order fit procedure in order to avoid nonophysical values (which I believe was the origin of strange features in the image ``example_in_focus'' in PIPE2D-615)
- blocks
-
PIPE2D-697 Analyze Subaru images and create a 2d PSF solution - fiber illumination constant
- In Progress
- relates to
-
PIPE2D-931 Speed up creation of variance images in psf modeling algorithm
- Done
-
PIPE2D-615 Illumination estimate of the pupil should be constant across different spots for single fiber
- Done
-
PIPE2D-928 Improve psf modelling with fiber illumination constant across spots in the same fiber
- Won't Fix