Compute 2nd moments for Med Res data

    XMLWordPrintable

    Details

    • Type: Task
    • Status: Done (View Workflow)
    • Priority: Normal
    • Resolution: Done
    • Affects Version/s: None
    • Fix Version/s: None
    • Component/s: None
    • Labels:
      None
    • Story Points:
      3
    • Sprint:
      2DDRP-2021 A

      Description

      With respect to determining the alignment for medium resolution exposures, as discussed today during the SpS hardware telecon, please compute using the 2D DRP second moments for the following medium-resolution HgAr visit sets:  

      3443...3450
      18052...18059

      and the following lines:

      696.7352, 727.494 , 795.0362, 912.5471, 966.0435

      Note that as the above data are based on the HgAr lamp, the continuum needs to be removed.

      These data would be used to compare with the plots generated by fmadec using the SEP python module (https://sep.readthedocs.io/en/v1.0.x/) in slide 12 of the following presentation: https://sumire.pbworks.com/w/file/fetch/140734437/LAM_Subaru_SM1_20200715.pdf