  2. PIPE2D-424

Investigate very wide traces

    XMLWordPrintable

    Details

    • Type: Task
    • Status: Done (View Workflow)
    • Priority: Normal
    • Resolution: Done
    • Affects Version/s: None
    • Fix Version/s: None
    • Component/s: None
    • Labels:
      None
    • Story Points:
      2

      Description

      Paul reports (slack, #drp-2d on Thursday, May 16th, 2019) that when analyzing the exposure with visitid=13183 he finds:

      that Here’s the width of each fiber (except the two close to each other):

      ```0 2.68939032411

      1 2.63398771636

      2 2.08473567312
      3 1.86881057574
      4 1.81323757688
      5 1.64066318482
      6 1.53396636169
      7 1.53255265524
      8 1.45133603564
      9 1.40209867151
      10 1.38059525031
      11 1.31285056784
      12 1.27757783073
      13 1.24954811736```
      Sure looks like optics to me, what with that tilt.

      This would imply huge differences between the PSF on the left and right hand side of the detector. I believe that this data should have been properly aligned, even thought they had the wrong stop (F/3.3)

      This ticket is to 1. investigate this claim, 2. see if this is still the case in the data taken with the F/2.8 stop .