Uploaded image for project: 'Instrument control development'
  1. Instrument control development
  2. INSTRM-754

fiberIds are incorrect in (at least) mcsData and CobraConfig tables

    XMLWordPrintable

    Details

    • Type: Bug
    • Status: Done (View Workflow)
    • Priority: Critical
    • Resolution: Done
    • Component/s: None
    • Labels:

      Description

      Looking at the data for e.g. visits BETWEEN 1762300 AND 1762349 I discovered that the fiberIds in the database are incorrect.  For example, for fiberIds 102..103 the figure shows that the spots at e.g. y = 960 are assigned to fibres 102 and 103.

       

      The problem also shows up in the mapping of nominal positions to fiberId:

       

      Note that as a function of visit number the fiberIds change

        Attachments

          Activity

            People

            • Assignee:
              chyan chyan
              Reporter:
              rhl rhl
              Reviewers:
              hassan
            • Votes:
              0 Vote for this issue
              Watchers:
              3 Start watching this issue

              Dates

              • Created:
                Updated:
                Resolved: