Gen2 is receiving some PFSC files with bad data secition

    XMLWordPrintable

    Details

    • Sprint:
      Engrun15Mar

      Description

      eric reported that Gen2 is getting some PFSC images whose data section doesn't match up with the size listed in the header. For expample, these files failed to open:

       'PFSC10504800.fits',
       'PFSC10504301.fits',
       'PFSC10505801.fits',
       'PFSC10505300.fits',
       'PFSC10500500.fits',
       'PFSC10504500.fits',
       'PFSC10505501.fits',
       'PFSC10507010.fits',
       'PFSC10506900.fits',
       'PFSC10507008.fits'

       

      Craig and Eric compared checksum for an image:

       

      cloomis@shell-ics:raw$ sha256sum 2024-01-17/mcs/PFSC10507008.fits
      51307b99c4c2c5e37407d8fa51419aa100c0c5a761e4613047760ee20ee9953a 2024-01-17/mcs/PFSC10507008.fits
      

      vs

      gen2@g2s2:/gen2/share/data/PFS$ sha256sum PFSC10507008.fits
      e3b0c44298fc1c149afbf4c8996fb92427ae41e4649b934ca495991b7852b855  PFSC10507008.fits