Cobra .xml file is missing two broken fiber of SM1

    XMLWordPrintable

    Details

    • Story Points:
      1
    • Sprint:
      preEngRun08Nov, PreEngRun09Dec

      Description

      Cobra xml file marks  broken fibers (in "Status" tag), and the latest version (20220923) has only 5 broken fibers, which are broken at Cable C. However,  there are two more broken fiber at Cable A, SM1. Namely,

      #mod #cm2 #sp #fh #fid
      4 2 1 3 3
      12 21 1 114 114

      I think these two fibers should be marked as broken fibers too. (Note: strictly speaking, fid=3 is fiber with very low transmission, not completely broken.)