Type: Task
-
Status: Done (View Workflow)
-
Priority: Normal
-
Resolution: Done
-
Component/s: None
-
Labels:
-
Story Points:4
-
Sprint:EngRun03
At the fitting test to Popt2, we found that we had missed definition of InR at installation. We assumed InR=0 at installation, but it supposed to be +90. As a result, InR operation range is limited from -180 to 270. (Note sign should be double checked by someone)
From the h/w point of view, both PFI and Pop2 has the limit switch, although one is to be installed at -180 deg. So s/w should limit operation range to protect PFI.
It is not sure on which level we should limit rotation, but Gen2 (by eric) should one place to limit operation.
- relates to
-
INSTRM-1353 Update transformation code to handle 90-degree offset
- Done
-
INSTRM-1354 Provide software limit to instrument rotator angle
- Won't Fix