<!-- 
RSS generated by JIRA (8.3.4#803005-sha1:1f96e09b3c60279a408a2ae47be3c745f571388b) at Sat Feb 10 16:27:41 JST 2024

It is possible to restrict the fields that are returned in this document by specifying the 'field' parameter in your request.
For example, to request only the issue key and summary append 'field=key&field=summary' to the URL of your request.
-->
<rss version="0.92" >
<channel>
    <title>PFS-JIRA</title>
    <link>https://pfspipe.ipmu.jp/jira</link>
    <description>This file is an XML representation of an issue</description>
    <language>en-us</language>    <build-info>
        <version>8.3.4</version>
        <build-number>803005</build-number>
        <build-date>13-09-2019</build-date>
    </build-info>


<item>
            <title>[INSTRM-693] Add autonomous warmup routine.</title>
                <link>https://pfspipe.ipmu.jp/jira/browse/INSTRM-693</link>
                <project id="10300" key="INSTRM">Instrument control development</project>
                    <description>&lt;p&gt;For when power is lost and/or communication to the piepan is cut off we need an independent warmup routine in the temperature board. Steve Hope will flesh out the specification and attach it to this ticket. But roughly speaking there will be some criterion for the board to decide on its own that it needs to keep the detector safe (some combo of loss of power, loss of networking, loss of keepalive commands, etc), and a simple procedure to follow at that point (for example: turn off PID loops, slow down sampling, switch to maintaining a 1-2K diff between a detector sensor and some other one). As simple and robust as is possible.&lt;/p&gt;

&lt;p&gt;This also requires the PCM to power things off, in order to minimize load on PFS and SM UPSes, so that heater power can me maintained as long as possible.&lt;/p&gt;</description>
                <environment></environment>
        <key id="13650">INSTRM-693</key>
            <summary>Add autonomous warmup routine.</summary>
                <type id="3" iconUrl="https://pfspipe.ipmu.jp/jira/secure/viewavatar?size=xsmall&amp;avatarId=10518&amp;avatarType=issuetype">Task</type>
                                            <priority id="10000" iconUrl="https://pfspipe.ipmu.jp/jira/images/icons/priorities/medium.svg">Normal</priority>
                        <status id="10002" iconUrl="https://pfspipe.ipmu.jp/jira/images/icons/statuses/generic.png" description="The issue is resolved, reviewed, and merged">Done</status>
                    <statusCategory id="3" key="done" colorName="green"/>
                                    <resolution id="10000">Done</resolution>
                                        <assignee username="cloomis">cloomis</assignee>
                                    <reporter username="cloomis">cloomis</reporter>
                        <labels>
                            <label>SPS</label>
                    </labels>
                <created>Tue, 9 Jul 2019 14:52:57 +0000</created>
                <updated>Wed, 8 Mar 2023 23:16:39 +0000</updated>
                            <resolved>Wed, 8 Mar 2023 23:16:39 +0000</resolved>
                                                                    <component>ics_xcu_smb</component>
                        <due></due>
                            <votes>0</votes>
                                    <watches>2</watches>
                                                                <comments>
                            <comment id="16111" author="hassan" created="Wed, 25 Sep 2019 21:08:38 +0000"  >&lt;p&gt;Passive warmup conducted today at LAM reveals that the detector temperature is approx 10K higher than that of the surrounding hardware. So while the aim is to still implement an autonomous warmup mechanism to ensure that the detector temperature is approx 20K higher, this ticket is no longer regarded as highest priority for pre-shipping.&lt;/p&gt;</comment>
                            <comment id="32375" author="cloomis" created="Wed, 8 Mar 2023 20:56:49 +0000"  >&lt;p&gt;After watching the visible and NIR cryostat warmups we have implemented something a fair bit simpler. The SMB heater loop compares the detector temp to the coldest temp, and if closer than 3K (by default, and settable) changes the set point.&lt;/p&gt;</comment>
                            <comment id="32376" author="cloomis" created="Wed, 8 Mar 2023 23:16:39 +0000"  >&lt;p&gt;Tagged 1.5.0&lt;/p&gt;</comment>
                    </comments>
                <issuelinks>
                            <issuelinktype id="10002">
                    <name>Duplicate</name>
                                                                <inwardlinks description="is duplicated by">
                                        <issuelink>
            <issuekey id="13744">INSTRM-755</issuekey>
        </issuelink>
                            </inwardlinks>
                                    </issuelinktype>
                    </issuelinks>
                <attachments>
                    </attachments>
                <subtasks>
                    </subtasks>
                <customfields>
                                                <customfield id="customfield_10500" key="com.atlassian.jira.plugins.jira-development-integration-plugin:devsummary">
                        <customfieldname>Development</customfieldname>
                        <customfieldvalues>
                            
                        </customfieldvalues>
                    </customfield>
                                                                                                                                                                                                            <customfield id="customfield_10010" key="com.pyxis.greenhopper.jira:gh-lexo-rank">
                        <customfieldname>Rank</customfieldname>
                        <customfieldvalues>
                            <customfieldvalue>0|02qpuc:i6001gtpi9</customfieldvalue>

                        </customfieldvalues>
                    </customfield>
                                                                                                                        <customfield id="customfield_10005" key="com.pyxis.greenhopper.jira:gh-sprint">
                        <customfieldname>Sprint</customfieldname>
                        <customfieldvalues>
                                <customfieldvalue id="61">SM1-2019 N</customfieldvalue>
    <customfieldvalue id="63">SM1-2019 O</customfieldvalue>

                        </customfieldvalues>
                    </customfield>
                                                                <customfield id="customfield_10002" key="com.atlassian.jira.plugin.system.customfieldtypes:float">
                        <customfieldname>Story Points</customfieldname>
                        <customfieldvalues>
                            <customfieldvalue>4.0</customfieldvalue>
                        </customfieldvalues>
                    </customfield>
                                                                                                                        </customfields>
    </item>
</channel>
</rss>