RSS generated by JIRA (8.3.4#803005-sha1:1f96e09b3c60279a408a2ae47be3c745f571388b) at Sat Feb 10 16:40:21 JST 2024

It is possible to restrict the fields that are returned in this document by specifying the 'field' parameter in your request.
For example, to request only the issue key and summary append 'field=key&field=summary' to the URL of your request.
-->
<rss version="0.92" >
<channel>
    <title>PFS-JIRA</title>
    <link>https://pfspipe.ipmu.jp/jira</link>
    <description>This file is an XML representation of an issue</description>
    <language>en-us</language>    <build-info>
        <version>8.3.4</version>
        <build-number>803005</build-number>
        <build-date>13-09-2019</build-date>
    </build-info>


<item>
            <title>[INSTRM-1855] Allow setting an interval between losing line power and shutting down BEE.</title>
                <link>https://pfspipe.ipmu.jp/jira/browse/INSTRM-1855</link>
                <project id="10300" key="INSTRM">Instrument control development</project>
                    <description>&lt;p&gt;The PCM has a mechanism for powering off ports based on input voltage, which is used to power down all but the components required to run the detector heater. This currently detects the clear switch from line power to battery power. It also detects dropping below a voltage which indicates that the batteries are getting exhausted. The current logic uses those to decide when to power off the BEE, etc.&lt;/p&gt;

&lt;p&gt;We would like a variant on that. Define the switch from line to battery power as &lt;tt&gt;t0&lt;/tt&gt;. After a configurable interval from &lt;tt&gt;t0&lt;/tt&gt;, if line power has not been restored, power off the BEE, etc.&lt;/p&gt;

&lt;p&gt;The BEE can independently mark &lt;tt&gt;t0&lt;/tt&gt;, or at least a decent proxy for that. So it will know when its power will be cut off and thus be able to shut itself down properly or do any other cleanup tasks.&lt;/p&gt;</description>
                <environment></environment>
        <key id="23235">INSTRM-1855</key>
            <summary>Allow setting an interval between losing line power and shutting down BEE.</summary>
                <type id="3" iconUrl="https://pfspipe.ipmu.jp/jira/secure/viewavatar?size=xsmall&amp;avatarId=10518&amp;avatarType=issuetype">Task</type>
                                            <priority id="10000" iconUrl="https://pfspipe.ipmu.jp/jira/images/icons/priorities/medium.svg">Normal</priority>
                        <status id="10002" iconUrl="https://pfspipe.ipmu.jp/jira/images/icons/statuses/generic.png" description="The issue is resolved, reviewed, and merged">Done</status>
                    <statusCategory id="3" key="done" colorName="green"/>
                                    <resolution id="10000">Done</resolution>
                                        <assignee username="shope">shope</assignee>
                                    <reporter username="cloomis">cloomis</reporter>
                        <labels>
                            <label>near-term</label>
                    </labels>
                <created>Fri, 3 Feb 2023 17:05:35 +0000</created>
                <updated>Fri, 7 Apr 2023 21:37:19 +0000</updated>
                            <resolved>Thu, 6 Apr 2023 16:01:10 +0000</resolved>
                                                                    <component>ics_xcu_pcm</component>
                        <due></due>
                            <votes>0</votes>
                                    <watches>2</watches>
                                                                <comments>
                            <comment id="32373" author="cloomis" created="Wed, 8 Mar 2023 14:28:30 +0000"  >&lt;p&gt;We realized that the PCM could use its second supply to trigger the shutdown, which is directly connected to line power: that supply will go from ~24V to 0V immediately, and we do not need to be clever about LiFePO4 internals. Hope is changing the PCM routine to do that.&lt;/p&gt;</comment>
                            <comment id="32533" author="cloomis" created="Thu, 6 Apr 2023 16:01:10 +0000"  >&lt;p&gt;This has been done and tested on SN3 at JHU. PCM Version 20230310-01&lt;/p&gt;

&lt;p&gt;SN2,SN3,SN4 have been upgraded. Will negotiate wth &lt;a href=&quot;https://pfspipe.ipmu.jp/jira/secure/ViewProfile.jspa?name=fmadec&quot; class=&quot;user-hover&quot; rel=&quot;fmadec&quot;&gt;fmadec&lt;/a&gt; about upgrading SN1 at LAM.&lt;/p&gt;

&lt;p&gt;Oh. We did not use the direct supply, since that is back-fed by the turbo when that spins down. Too confusing to use.&lt;/p&gt;</comment>
                            <comment id="32541" author="fmadec" created="Fri, 7 Apr 2023 14:38:45 +0000"  >&lt;p&gt;no problem for me. Can that update be done while camera is cold ?&lt;br/&gt;
if yes, you can do it whenever you want&lt;br/&gt;
if no, sometimes end of next week, nir-sn2 should be warm&lt;/p&gt;</comment>
                            <comment id="32542" author="cloomis" created="Fri, 7 Apr 2023 21:37:19 +0000"  >&lt;p&gt;Updating the PCM firmware power-cycles everything including the BEE. So we should wait until nir-sn2 is warm.&lt;/p&gt;</comment>
                    </comments>
                <issuelinks>
                            <issuelinktype id="10003">
                    <name>Relates</name>
                                            <outwardlinks description="relates to">
                                        <issuelink>
            <issuekey id="23236">INSTRM-1856</issuekey>
        </issuelink>
                            </outwardlinks>
                                                        </issuelinktype>
                    </issuelinks>
                <attachments>
                    </attachments>
                <subtasks>
                    </subtasks>
                <customfields>
                                                <customfield id="customfield_10500" key="com.atlassian.jira.plugins.jira-development-integration-plugin:devsummary">
                        <customfieldname>Development</customfieldname>
                        <customfieldvalues>
                            
                        </customfieldvalues>
                    </customfield>
                                                                                                                                                                                                            <customfield id="customfield_10010" key="com.pyxis.greenhopper.jira:gh-lexo-rank">
                        <customfieldname>Rank</customfieldname>
                        <customfieldvalues>
                            <customfieldvalue>0|02qpjd:00r3000k0018</customfieldvalue>

                        </customfieldvalues>
                    </customfield>
                                                                                                                        <customfield id="customfield_10005" key="com.pyxis.greenhopper.jira:gh-sprint">
                        <customfieldname>Sprint</customfieldname>
                        <customfieldvalues>
                                <customfieldvalue id="163">PreEng11Apr1</customfieldvalue>

                        </customfieldvalues>
                    </customfield>
                                                                                                                                                    </customfields>
    </item>
</channel>
</rss>