RSS generated by JIRA (8.3.4#803005-sha1:1f96e09b3c60279a408a2ae47be3c745f571388b) at Sat Feb 10 16:31:47 JST 2024

It is possible to restrict the fields that are returned in this document by specifying the 'field' parameter in your request.
For example, to request only the issue key and summary append 'field=key&field=summary' to the URL of your request.
-->
<rss version="0.92" >
<channel>
    <title>PFS-JIRA</title>
    <link>https://pfspipe.ipmu.jp/jira</link>
    <description>This file is an XML representation of an issue</description>
    <language>en-us</language>    <build-info>
        <version>8.3.4</version>
        <build-number>803005</build-number>
        <build-date>13-09-2019</build-date>
    </build-info>


<item>
            <title>[INSTRM-1090] Change H4 horizontal readout direction</title>
                <link>https://pfspipe.ipmu.jp/jira/browse/INSTRM-1090</link>
                <project id="10300" key="INSTRM">Instrument control development</project>
                    <description>&lt;p&gt;The default readout configuration for the H4 swaps direction between channels: &lt;tt&gt;&amp;lt;-- -&lt;del&gt;&amp;gt; &amp;lt;&lt;/del&gt;- --&amp;gt;&lt;/tt&gt;, etc. But the ASIC internally corrects this so that the delivered image has all pixels sequenced from left-to-right. Fine.&lt;/p&gt;

&lt;p&gt;Fine, until you use IRP, especially N:1 IRP with N&amp;gt;1. Then that scheme gets very confusing: since the origin of the IRP sequence is at the start of the readout we will need to interpolate accounting for that orientation, but making the readout orientation the same for all channels by flipping alternate ones then makes the channel &lt;em&gt;images&lt;/em&gt; flip to the wrong order.&lt;/p&gt;

&lt;p&gt;But that H4 readout ordering can be changed to &lt;tt&gt;--&amp;gt; --&amp;gt; --&amp;gt; --&amp;gt;&lt;/tt&gt;, etc. I think that would make life less confusing and processing code less buggy: we still need to process the channels individually for non-trivial interleaving, but at least we won&apos;t need to flip back&amp;amp;forth. For non-IRP, there is essentially no difference unless you are hunting down injected electronic noise, etc. For the &lt;em&gt;existing&lt;/em&gt; 1:1 IRP reads there is also little difference: since each data pixel is paired with its one reference pixel the reference image does not need interpolation.&lt;/p&gt;</description>
                <environment></environment>
        <key id="14931">INSTRM-1090</key>
            <summary>Change H4 horizontal readout direction</summary>
                <type id="3" iconUrl="https://pfspipe.ipmu.jp/jira/secure/viewavatar?size=xsmall&amp;avatarId=10518&amp;avatarType=issuetype">Task</type>
                                            <priority id="10000" iconUrl="https://pfspipe.ipmu.jp/jira/images/icons/priorities/medium.svg">Normal</priority>
                        <status id="10100" iconUrl="https://pfspipe.ipmu.jp/jira/images/icons/statuses/generic.png" description="No further work should be done on this.">Won&apos;t Fix</status>
                    <statusCategory id="3" key="done" colorName="green"/>
                                    <resolution id="2">Won&apos;t Fix</resolution>
                                        <assignee username="cloomis">cloomis</assignee>
                                    <reporter username="cloomis">cloomis</reporter>
                        <labels>
                            <label>NIR</label>
                            <label>SPS</label>
                    </labels>
                <created>Thu, 15 Oct 2020 14:11:47 +0000</created>
                <updated>Wed, 12 Apr 2023 20:25:34 +0000</updated>
                            <resolved>Tue, 17 Nov 2020 19:50:14 +0000</resolved>
                                                                    <component>hxhal</component>
                    <component>ics_hxActor</component>
                        <due></due>
                            <votes>0</votes>
                                    <watches>1</watches>
                                                                <comments>
                            <comment id="18055" author="cloomis" created="Tue, 17 Nov 2020 19:50:14 +0000"  >&lt;p&gt;Can&apos;t fix, actually: the IRP ASIC firmware does not support changing readout direction from the H4 ROIC.&lt;/p&gt;</comment>
                            <comment id="32554" author="cloomis" created="Wed, 12 Apr 2023 20:25:34 +0000"  >&lt;p&gt;For future reference, Eddie later restored that feature in the IRP firmware. So we &lt;b&gt;could&lt;/b&gt; switch if we wanted to.&lt;/p&gt;</comment>
                    </comments>
                <issuelinks>
                            <issuelinktype id="10003">
                    <name>Relates</name>
                                                                <inwardlinks description="relates to">
                                        <issuelink>
            <issuekey id="11137">DAMD-7</issuekey>
        </issuelink>
            <issuelink>
            <issuekey id="14714">INSTRM-1069</issuekey>
        </issuelink>
                            </inwardlinks>
                                    </issuelinktype>
                    </issuelinks>
                <attachments>
                    </attachments>
                <subtasks>
                    </subtasks>
                <customfields>
                                                <customfield id="customfield_10500" key="com.atlassian.jira.plugins.jira-development-integration-plugin:devsummary">
                        <customfieldname>Development</customfieldname>
                        <customfieldvalues>
                            
                        </customfieldvalues>
                    </customfield>
                                                                                                                                                                                                            <customfield id="customfield_10010" key="com.pyxis.greenhopper.jira:gh-lexo-rank">
                        <customfieldname>Rank</customfieldname>
                        <customfieldvalues>
                            <customfieldvalue>0|02qpuc:i6001gr068fhw9qo4o0kc</customfieldvalue>

                        </customfieldvalues>
                    </customfield>
                                                                                                                        <customfield id="customfield_10005" key="com.pyxis.greenhopper.jira:gh-sprint">
                        <customfieldname>Sprint</customfieldname>
                        <customfieldvalues>
                                <customfieldvalue id="84">SM1PD-2020 K</customfieldvalue>
    <customfieldvalue id="89">SM1PD-2020 L</customfieldvalue>

                        </customfieldvalues>
                    </customfield>
                                                                <customfield id="customfield_10002" key="com.atlassian.jira.plugin.system.customfieldtypes:float">
                        <customfieldname>Story Points</customfieldname>
                        <customfieldvalues>
                            <customfieldvalue>1.0</customfieldvalue>
                        </customfieldvalues>
                    </customfield>
                                                                                                                        </customfields>
    </item>
</channel>
</rss>