[PIPE2D-944] Processing fails when reducing b-band continuum data and modifying detectormap Created: 11/Nov/21  Updated: 16/Dec/21  Resolved: 16/Dec/21

Status: Done
Project: DRP 2-D Pipeline
Component/s: None
Affects Version/s: None
Fix Version/s: None

Type: Task Priority: Normal
Reporter: hassan Assignee: price
Resolution: Done Votes: 0
Labels: None
Remaining Estimate: Not Specified
Time Spent: Not Specified
Original Estimate: Not Specified

Story Points: 4
Sprint: 2DDRP-2021 A12
Reviewers: ncaplar

 Description   

This was reported on the #drp-2d slack channel 2021-10-09 by Neven Caplar.

When running reduceExposure against b-band continuum data, the processing fails:

https://gist.github.com/nevencaplar/08d6532809090a9053b4a36b68ad38b0

This can be circumvented by setting photometerLines.doApertureCorrection=False, but this would mean that the processing would not yield an adjusted detectormap.

The basic problem is that continuum is not recognized as an lamp - nor there are procedures to process continuum data.  The image gets processed as sky frame and obviously line identification fails and detectorMap adjustment fails.

Please update the code to ensure that an adjusted detectormap can be generated while processing continuum data.



 Comments   
Comment by price [ 10/Dec/21 ]

ncaplar, since hassan is on holidays, would you please check that this works for you?

There are two commits on tickets/PIPE2D-944 of drp_stella.

Comment by price [ 16/Dec/21 ]

ncaplar reports on the GitHub PR that it's fine.

Merged.