[PIPE2D-555] Verify that adding higher-order Zernike from defocused images improves the focused image fit Created: 14/Apr/20  Updated: 13/Jan/22

Status: Open
Project: DRP 2-D Pipeline
Component/s: None
Affects Version/s: None
Fix Version/s: None

Type: Task Priority: Normal
Reporter: ncaplar Assignee: ncaplar
Resolution: Unresolved Votes: 0
Labels: None
Remaining Estimate: Not Specified
Time Spent: Not Specified
Original Estimate: Not Specified

Issue Links:
Relates
relates to PIPE2D-354 Estimate high-order Zernike from defo... Done
relates to PIPE2D-553 Estimate higher-order Zernike terms f... Done
Story Points: 4

 Description   

This ticket is to verify that adding the Higher-order Zernike parameters estimated from defocused images actually improves the quality of the focused images, i.e., that the higher-order estimates are worth doing. 

One issue - how do we actually implement these high-order Zernike wavefront components into our analysis? At the moment for low-order components I simply conduct a linear fit of the Zernike amplitude as a function of defocus. It is not obvious that this will be possible for very high order Zernikes (due to possible degeneracies and low amplitudes). I will probably need to add a ticket dealing with this problem.

 

 


Generated at Sun Apr 13 02:34:14 JST 2025 using Jira 8.3.4#803005-sha1:1f96e09b3c60279a408a2ae47be3c745f571388b.