[PIPE2D-272] Update CR and tracing configuration Created: 21/Feb/18 Updated: 06/Apr/18 Resolved: 06/Apr/18 |
|
| Status: | Done |
| Project: | DRP 2-D Pipeline |
| Component/s: | None |
| Affects Version/s: | None |
| Fix Version/s: | None |
| Type: | Task | Priority: | Normal |
| Reporter: | cloomis | Assignee: | cloomis |
| Resolution: | Done | Votes: | 0 |
| Labels: | None | ||
| Remaining Estimate: | Not Specified | ||
| Time Spent: | Not Specified | ||
| Original Estimate: | Not Specified | ||
| Description |
|
The default cosmic ray detection configuration is not correct for PFS. Specifically, the PSF is quite sharp, and emission lines can be picked up as CRs. A first cut with RHL yielded a few changes: config.repair.cosmicray.cond3_fac = 4 config.repair.cosmicray.cond3_fac2 = 1 config.repair.cosmicray.minSigma = 10.0 config.repair.cosmicray.min_DN = 500.0 Additionally, the fiber trace extraction profile is a bit wide, and picks up a few pixels from the neighboring fibers. For the moment, limiting to +/- 3.5 pixels defers having to worry about real overlap from wings. |
| Comments |
| Comment by cloomis [ 06/Apr/18 ] |
|
Merged in f333948 |