[PIPE2D-272] Update CR and tracing configuration Created: 21/Feb/18  Updated: 06/Apr/18  Resolved: 06/Apr/18

Status: Done
Project: DRP 2-D Pipeline
Component/s: None
Affects Version/s: None
Fix Version/s: None

Type: Task Priority: Normal
Reporter: cloomis Assignee: cloomis
Resolution: Done Votes: 0
Labels: None
Remaining Estimate: Not Specified
Time Spent: Not Specified
Original Estimate: Not Specified


 Description   

The default cosmic ray detection configuration is not correct for PFS. Specifically, the PSF is quite sharp, and emission lines can be picked up as CRs.

A first cut with RHL yielded a few changes:

config.repair.cosmicray.cond3_fac = 4
config.repair.cosmicray.cond3_fac2 = 1
config.repair.cosmicray.minSigma = 10.0
config.repair.cosmicray.min_DN = 500.0

Additionally, the fiber trace extraction profile is a bit wide, and picks up a few pixels from the neighboring fibers. For the moment, limiting to +/- 3.5 pixels defers having to worry about real overlap from wings.



 Comments   
Comment by cloomis [ 06/Apr/18 ]

Merged in f333948