[PIPE2D-18] Solve for per-fibre wavelength solution given an arc exposure Created: 18/Jul/14 Updated: 17/Jun/16 Resolved: 17/Jun/16 |
|
| Status: | Done |
| Project: | DRP 2-D Pipeline |
| Component/s: | None |
| Affects Version/s: | None |
| Fix Version/s: | None |
| Type: | Story | Priority: | Major |
| Reporter: | rhl | Assignee: | Unassigned |
| Resolution: | Done | Votes: | 0 |
| Labels: | None | ||
| Remaining Estimate: | Not Specified | ||
| Time Spent: | Not Specified | ||
| Original Estimate: | Not Specified | ||
| Issue Links: |
|
||||||||||||
| Epic Link: | Wavelength Solution | ||||||||||||
| Reviewers: | aritter | ||||||||||||
| Comments |
| Comment by aritter [ 17/Jun/16 ] |
|
Wavelength calibration of arc spectra works with an RMS of 0.02-0.05 Angstroems, measured from lines held back from the calibration procedure |
| Comment by aritter [ 17/Jun/16 ] |
|
Emission line identification and wavelength calibration have been implemented. Currently a by-hand identified reference spectrum is needed to compare to the spectrum to be calibrated. Creating the line list for each automatically from the pixel->wavelength mapper is currently being bug-fixed. |