[PIPE2D-1331] ingest calibration product for N2 ( defects and flat) Created: 16/Nov/23  Updated: 29/Nov/23  Resolved: 29/Nov/23

Status: Done
Project: DRP 2-D Pipeline
Component/s: None
Affects Version/s: None
Fix Version/s: None

Type: Task Priority: Normal
Reporter: arnaud.lefur Assignee: Unassigned
Resolution: Done Votes: 0
Labels: EngRun
Remaining Estimate: Not Specified
Time Spent: Not Specified
Original Estimate: Not Specified

Sprint: EDR+AIT

 Description   

Automatic reduction does not work as we don't have the required calibration products :

we need :

  • flat ( can be a fake one for a start)
  • defects map

From the butler, it seems that we're using a 3x3 kernel for IPC, so we don't use Eddie IPC maps for now.
Do we have a kernel for n2 cloomis ?



 Comments   
Comment by arnaud.lefur [ 29/Nov/23 ]

I've installed n2 calib in 2023-11-v4, using ipc kernel from cloomis
note that,as for n3, we're using a fake flat (all 1)
I didn't had a new defect so it's still using default defects which I ignore the provenance.

CALIB-2023-11-v4/defects/2020-01-01T00:00:00/defects-2020-01-01T00:00:00-05.fits

This will need to be rebuilt but at least crude ISR now works.