[PIPE2D-1331] ingest calibration product for N2 ( defects and flat) Created: 16/Nov/23 Updated: 29/Nov/23 Resolved: 29/Nov/23 |
|
| Status: | Done |
| Project: | DRP 2-D Pipeline |
| Component/s: | None |
| Affects Version/s: | None |
| Fix Version/s: | None |
| Type: | Task | Priority: | Normal |
| Reporter: | arnaud.lefur | Assignee: | Unassigned |
| Resolution: | Done | Votes: | 0 |
| Labels: | EngRun | ||
| Remaining Estimate: | Not Specified | ||
| Time Spent: | Not Specified | ||
| Original Estimate: | Not Specified | ||
| Sprint: | EDR+AIT |
| Description |
|
Automatic reduction does not work as we don't have the required calibration products : we need :
From the butler, it seems that we're using a 3x3 kernel for IPC, so we don't use Eddie IPC maps for now. |
| Comments |
| Comment by arnaud.lefur [ 29/Nov/23 ] |
|
I've installed n2 calib in 2023-11-v4, using ipc kernel from cloomis CALIB-2023-11-v4/defects/2020-01-01T00:00:00/defects-2020-01-01T00:00:00-05.fits This will need to be rebuilt but at least crude ISR now works. |