[PIPE2D-1069] Process June 2022 PFI non-uniformity data Created: 12/Aug/22  Updated: 17/Aug/22  Resolved: 17/Aug/22

Status: Done
Project: DRP 2-D Pipeline
Component/s: None
Affects Version/s: None
Fix Version/s: None

Type: Task Priority: Normal
Reporter: hassan Assignee: hassan
Resolution: Done Votes: 0
Labels: None
Remaining Estimate: Not Specified
Time Spent: Not Specified
Original Estimate: Not Specified

Attachments: PNG File PFI_scaledflux_June2022.png     PNG File PFI_scaledflux_Sep2021.png    
Issue Links:
Relates
relates to PIPE2D-902 Measure the flux of calibration lamps... Done

 Description   

yuki.moritani has acquired visits 76389..76398 to study the apparent non-uniformity of the illumination of fibers on the PFI, which appears to vary as a function of instrument angle (InR).

Please process these visits.



 Comments   
Comment by hassan [ 17/Aug/22 ]

The actual valid visits are 76389..76396^76398, as visit 76397 is not an SPS exposure.

Note that for those valid visits, a 100W halogen lamp was used, replacing a 50W halogen lamp. The latter lamp was used for earlier data taken during Sept 2021 for a similar experiment (visits 68424..68427). See also PIPE2D-902.

Comment by hassan [ 17/Aug/22 ]

June 2022 data processed by DRP using the following command line:

reduceExposure.py /projects/HSC/PFS/Subaru --calib /projects/HSC/PFS/Subaru/CALIB-20220630 --rerun hassans/dev/pipe2d-1069-20220812a --id visit=76389..76397^76398 arm=b^r -c isr.doFlat=False isr.doWrite=True repair.doCosmicRay=False

The Sep 2021 data were re-processed following the same prescription.

The integrated flux for each fiber across the r band were computed from the pfsArm data and scaled according to the following formula: (flux-refFlux)/np.median(refFlux) where flux is the original integrated flux array (one element per fiber), refFlux and the corresponding integrated flux array for a 'reference' visit, 76398 with instrument rotator InR of 90deg, from the same June 2022 group of visits.

For each visit, the scaled flux for each fiber is plotted in PFI_mm coordinates using the cobra design position taken from the Grand Fiber Map, as shown in PFI_scaledflux_June2022.png.

The data from the Sept 2021 run were plotted similarly, using the reference visit 68426, again with InR=90deg. See PFI_scaledflux_Sep2021.png.

The structure that was noticed originally in the Sept 2021 data is unfortunately still apparent in the June 2022 data. Look in particular at visit 76391 (InR=-90deg) in the June 2022 data, and compare that with that for visit 68424 (same InR) in the Sep 2021 data.

Comment by hassan [ 17/Aug/22 ]

Jupyter notebook used committed to github: https://github.com/Subaru-PFS/dev_2ddrp/blob/master/notebooks/PIPE2D-1069%20(June2022%20PFI%20non-uniformity).ipynb

Generated at Sat Feb 10 16:02:20 JST 2024 using Jira 8.3.4#803005-sha1:1f96e09b3c60279a408a2ae47be3c745f571388b.