[INSTRM-94] Setting CCD0 serial number clears the CCD1 serial number Created: 10/Feb/17  Updated: 18/Mar/23  Resolved: 18/Mar/23

Status: Done
Project: Instrument control development
Component/s: ics_xcu_fee
Affects Version/s: None
Fix Version/s: None

Type: Task Priority: Major
Reporter: cloomis Assignee: shope
Resolution: Done Votes: 0
Labels: None
Remaining Estimate: Not Specified
Time Spent: Not Specified
Original Estimate: Not Specified


 Description   

Setting the CCD0 serial number clears the CCD1 serial number. Other way is OK.

Using the raw FEE commands:

Starting with both set to unknown:

pfs@pfsDevSvr:~$ oneCmd.py ccd_r7 fee raw=gs,CCD0
2017-02-09T20:01:03.347 ccd_r7 : text="returned: unknown"
pfs@pfsDevSvr:~$ oneCmd.py ccd_r7 fee raw=gs,CCD1
2017-02-09T20:01:06.548 ccd_r7 : text="returned: unknown"

Set CCD0 to urk:

pfs@pfsDevSvr:~$ oneCmd.py ccd_r7 fee raw=ss,CCD0,urk
2017-02-09T20:01:37.786 ccd_r7 : text="returned: SUCCESS"

Then check both:

pfs@pfsDevSvr:~$ oneCmd.py ccd_r7 fee raw=gs,CCD0
2017-02-09T20:01:42.586 ccd_r7 : text="returned: urk"
pfs@pfsDevSvr:~$ oneCmd.py ccd_r7 fee raw=gs,CCD1
2017-02-09T20:01:45.786 ccd_r7 : text="returned: "


 Comments   
Comment by cloomis [ 28/Jun/17 ]

Does not work for me, using 20170613-03

Comment by arnaud.lefur [ 18/Mar/23 ]

fixed.