[INSTRM-57] [xcuActor] Handle multi-line responses to raw device commands Created: 27/Dec/16  Updated: 30/May/18  Resolved: 30/May/18

Status: Done
Project: Instrument control development
Component/s: None
Affects Version/s: None
Fix Version/s: None

Type: Task Priority: Major
Reporter: cloomis Assignee: cloomis
Resolution: Done Votes: 0
Labels: None
Remaining Estimate: Not Specified
Time Spent: Not Specified
Original Estimate: Not Specified


 Description   

This issue was initially filed into JIRA by 'cloomis' at 17/Mar/16 3:05 PM as ICS-28.

Some devices can return multiple responses to a single command, but without any final delimiter. Notably the Sunpower controller, grr.

I suggest added a timeout argument to the "raw" command(s), where the actor will continue to fetch data until the device has been silent for that long. There could be other schemes, but this seems general and sufficient.



 Comments   
Comment by hassan [ 30/May/18 ]

Sunpower issue fixed. Rest covered by INSTRM-55.