[INSTRM-442] sequencePanel cmd error when comments are set with a non spsait command Created: 31/Jul/18 Updated: 22/Aug/18 Resolved: 22/Aug/18 |
|
| Status: | Done |
| Project: | Instrument control development |
| Component/s: | ics_sequencePanel |
| Affects Version/s: | None |
| Fix Version/s: | None |
| Type: | Bug | Priority: | Normal |
| Reporter: | fmadec | Assignee: | arnaud.lefur |
| Resolution: | Done | Votes: | 0 |
| Labels: | SM1 | ||
| Remaining Estimate: | Not Specified | ||
| Time Spent: | Not Specified | ||
| Original Estimate: | Not Specified | ||
| Epic Link: | SM1 Phase Three |
| Description |
|
12:19:16.376457 cmdIn=sac ccd background exptime=4 comments="background" 12:19:16.562620 sac f text="Unmatched command: ccd background exptime=4 comments=\"background\" (exception: Invalid cmd: ccd background exptime=\"4\" comments=\"background\")" 12:19:35.892701 cmdIn=sac ccd background exptime=15 comments="bck" 12:19:36.108588 sac f text="Unmatched command: ccd background exptime=15 comments=\"bck\" (exception: Invalid cmd: ccd background exptime=\"15\" comments=\"bck\")" 12:20:01.892569 cmdIn= comments="sac ccd expose exptime=15" |
| Comments |
| Comment by arnaud.lefur [ 02/Aug/18 ] |
|
I think there is a misuse in someway. Because for the type "Command" name and comment columns should be disabled. I suspect you have copy + paste a sacAlign sequence and then replace the spsait command with a sac command. It's failing because sequencePanel is parsing the name and comments as an argument and SacActor doesn't have those. |
| Comment by arnaud.lefur [ 22/Aug/18 ] |
|
I've made it a bit more robust merged in 5762036 |