[INSTRM-365] Values above 50°C seems to be filtered Created: 17/May/18 Updated: 04/Jul/18 Resolved: 04/Jul/18 |
|
| Status: | Done |
| Project: | Instrument control development |
| Component/s: | ics_sps_engineering_plotData |
| Affects Version/s: | None |
| Fix Version/s: | None |
| Type: | Bug | Priority: | Normal |
| Reporter: | fmadec | Assignee: | arnaud.lefur |
| Resolution: | Done | Votes: | 0 |
| Labels: | None | ||
| Remaining Estimate: | Not Specified | ||
| Time Spent: | Not Specified | ||
| Original Estimate: | Not Specified | ||
| Description |
|
Values above 50°C seems to be filtered, while during bakeout cryostat body temperature body is higher than 50°C. I think If data are filtered we should have a flag to disable it, just to to be more generic, ideally we should be able to set the threshold values via the gui. |
| Comments |
| Comment by arnaud.lefur [ 04/Jun/18 ] |
|
There is a config file which defines those treshold in $ICS_SPS_ENGINEERING_LIB_DATAQUERY_DIR/config/datatype.cfg It's true that we can reach 50°C during bakeout, so I've just set the value to 70°C. We should be okay now. |