[INSTRM-274] Sequencer is no longer per sm Created: 11/Jan/18  Updated: 04/Jul/18  Resolved: 04/Jul/18

Status: Done
Project: Instrument control development
Component/s: ics_spsaitActor
Affects Version/s: None
Fix Version/s: None

Type: Task Priority: Normal
Reporter: arnaud.lefur Assignee: arnaud.lefur
Resolution: Done Votes: 0
Labels: SM1
Remaining Estimate: Not Specified
Time Spent: Not Specified
Original Estimate: Not Specified

Sprint: 2017-10A

 Description   

At some point, I was thinking that we would need a sequencer per sm:
spsait_sm1, spsait_sm2 ...
My point was mainly to simplify the commands, because in that case I didn't need to parse spectrograph module ID

But Craig suggested that in fact, we need only one sequencer and a place to store the current hardware configuration (ics_config ultimately) .

that would give :
sps=sm1,sm2
sm1=blue,red
sm2=blue

by default, If I do an exposure, spsait will know which spectrograph and which arm to command.

I think that's fairly simple and flexible.



 Comments   
Comment by arnaud.lefur [ 04/Jun/18 ]

I've added cams=b1,r1 ...into the config file.

By default, the cam list is loaded from there but it can optionally be specified in the expose command  [<cam>] [<cams>]

Comment by arnaud.lefur [ 04/Jul/18 ]

merged in dc2284e