[INSTRM-2135] iic resuceBoreseightData didn't calculate boresight nor write it on opDB Created: 23/Dec/23 Updated: 31/Jan/24 |
|
| Status: | Open |
| Project: | Instrument control development |
| Component/s: | ics_iicActor |
| Affects Version/s: | None |
| Fix Version/s: | None |
| Type: | Task | Priority: | Normal |
| Reporter: | yuki.moritani | Assignee: | cloomis |
| Resolution: | Unresolved | Votes: | 0 |
| Labels: | EngRun | ||
| Remaining Estimate: | Not Specified | ||
| Time Spent: | Not Specified | ||
| Original Estimate: | Not Specified | ||
| Description |
|
When we ran Gen2 script for boresight measurement, iic didn't calculate it. Here is a log around that time. 2023-12-22 07:17:58.733Z cmds 20 Actor.py:524 new cmd: reduceBoresightData 2023-12-22 07:17:58.733Z cmds 20 CommandLink.py:122 > 0 0 d 1703229478.7333412 thread has started .run() 2023-12-22 07:17:58.734Z cmds 20 CommandLink.py:122 > 2 408 i subCommand=30180,12,"fps calculateBoresight startFrame=10333500 endFrame=10333511",-1,"" 2023-12-22 07:17:58.734Z resourceManager 20 resourceManager.py:142 locking resources : mcs,fps 2023-12-22 07:17:58.769Z cmds 20 CommandLink.py:122 > 2 408 f text="event execute inappropriate in current state FINISHED" 2023-12-22 07:17:58.769Z resourceManager 20 resourceManager.py:158 freeing resources : mcs,fps 2023-12-22 07:17:58.769Z cmds 20 CommandLink.py:122 > 0 0 d returnQueue=None ret=None 2 Also fps doesn't write calculated position on opDB; "writeToDB" option is needed. it will be nice if we have an option to write the result to opdb, |