[INSTRM-2066] Adjust power-on mask for PCMs Created: 12/Sep/23 Updated: 11/Oct/23 Resolved: 11/Oct/23 |
|
| Status: | Done |
| Project: | Instrument control development |
| Component/s: | None |
| Affects Version/s: | None |
| Fix Version/s: | None |
| Type: | Task | Priority: | Normal |
| Reporter: | cloomis | Assignee: | cloomis |
| Resolution: | Done | Votes: | 0 |
| Labels: | EngRun | ||
| Remaining Estimate: | Not Specified | ||
| Time Spent: | Not Specified | ||
| Original Estimate: | Not Specified | ||
| Description |
|
The PCMs have a mask of which ports to automatically power up when the PCM is turned on. As shipped from IDG, that is engineering- or checkout- oriented: onlybthe BEE is powered up. Once a cryostat is checked out, that should be flipped: most/all ports should be enabled by default. In particular, once a cryostat has been checkout out at Subaru, that mask should be changed. Do so as they get delivered. |
| Comments |
| Comment by cloomis [ 14/Sep/23 ] |
|
Fabrice suggests leaving the FEE off, and probably the coolers too. |
| Comment by cloomis [ 11/Oct/23 ] |
|
Done for sm1-3. on: motors, gauge, temps, bee, interlock for c in n1 n3 b1 r1 b2 r2 b3 r3; do
oneCmd.py xcu_$c pcm setMask powerOn mask=01011011
done
|