[INSTRM-1990] PFI temperature sensor for EBOX1 and EBOX2 is mislabeled Created: 06/Jun/23 Updated: 24/Aug/23 Resolved: 24/Aug/23 |
|
| Status: | Done |
| Project: | Instrument control development |
| Component/s: | ics_pebActor |
| Affects Version/s: | None |
| Fix Version/s: | None |
| Type: | Bug | Priority: | Normal |
| Reporter: | yuki.moritani | Assignee: | chyan |
| Resolution: | Done | Votes: | 0 |
| Labels: | None | ||
| Remaining Estimate: | Not Specified | ||
| Time Spent: | Not Specified | ||
| Original Estimate: | Not Specified | ||
| Attachments: |
|
| Description |
|
By touching the temperature sensor for EBOX 1,2,3, it was found that the sensors for EBOX 1 and EBOX2 were labelled flipped. |
| Comments |
| Comment by yuki.moritani [ 19/Jun/23 ] |
|
We confirmed the wiring of the temperature sensor inside the old Ebox is the same as the new E-box. We also confirmed wiring inside the old E-box is correct for AG3 and AG4 . Looking the graph when the AG cameras were cooled down one by one (AG6 -> AG5 -> AG4 -> AG3 -> AG2 -> AG1), the new box also show that the value AG3 and AG4 are flipped.
|
| Comment by chyan [ 19/Jun/23 ] |
|
If the wiring of both E-boxes are correct and consistent. Should we correct in software side? |