[INSTRM-1962] Fixing reportTEC bug when using three AG cameras Created: 30/Apr/23  Updated: 30/Apr/23  Resolved: 30/Apr/23

Status: Done
Project: Instrument control development
Component/s: ics_agccActor
Affects Version/s: None
Fix Version/s: None

Type: Task Priority: Normal
Reporter: chyan Assignee: chyan
Resolution: Done Votes: 0
Labels: None
Remaining Estimate: Not Specified
Time Spent: Not Specified
Original Estimate: Not Specified


 Description   
2023-04-29 22:04:30.973Z cmds             20 Actor.py:525 new cmd: expose object visit=92715 exptime=5.0 centroid=1
2023-04-29 22:04:30.988Z cmds             20 CommandLink.py:121 > 2 4 i text="read magFit = [-2.227, 27.66]"
2023-04-29 22:04:30.988Z cmds             20 CommandLink.py:121 > 2 4 i text="found cameras: [1, 3, 5]"
2023-04-29 22:04:30.988Z cmds             20 CommandLink.py:121 > 2 4 i text="Number of AG cameras = 3"
2023-04-29 22:04:30.994Z cmds             20 CommandLink.py:121 > 2 4 f text="command failed: AttributeError(\"'NoneType' object has no attribute 'getTemperature'\") in reportTEC() at /software/mhs/products/Linux64/ics_agccActor/1.2.1/lib/python/agccActor/camera.py:83"