[INSTRM-1847] Add broken fiber of Cable B3 to Cobra xml file. Created: 25/Jan/23  Updated: 30/Nov/23  Resolved: 24/Nov/23

Status: Done
Project: Instrument control development
Component/s: pfs_instdata
Affects Version/s: None
Fix Version/s: None

Type: Task Priority: Normal
Reporter: yuki.moritani Assignee: chyan
Resolution: Done Votes: 0
Labels: EngRun, PFI
Remaining Estimate: Not Specified
Time Spent: Not Specified
Original Estimate: Not Specified

Issue Links:
Relates
relates to INSTRM-2092 Check mask of Broken Fibers in xml file Done
relates to INSTRM-2114 cobraId 2182, fiberId 820 is consiste... Done
Sprint: EDR+AIT

 Description   

Recently we found that one fiber had been broken, likely during shipping from Brazil to Hawaii. The broken fiber in MTP U2-3 group in the Cable B3, hole #16 on BC side. This fiber is supposed to connect fiberId=820, CobraId=2182 (Cobra SC39, PFI=11).

The Cobra xml file should be updated accordingly.



 Comments   
Comment by chyan [ 24/Nov/23 ]

Would you please confirm the cobra information? fiberId=820, CobraId=2182 should be (Cobra SC39, positionerId=16).

Comment by arnaud.lefur [ 30/Nov/23 ]

that's correct.
Yes I still see this cobra flagged as COBRA_OK_MASK in the latest pfs_instdata version

Comment by yuki.moritani [ 30/Nov/23 ]

At an informal meeting for ICS-PFI+MCS, Chi-Hung reported that he would upload the latest xml (covering INSTRM-1847 and INSTRM-2092) when working on INSTRM-1643.

Generated at Sat Feb 10 16:40:14 JST 2024 using Jira 8.3.4#803005-sha1:1f96e09b3c60279a408a2ae47be3c745f571388b.