[INSTRM-160] Add darktime= argumnt to the expose readout command Created: 28/Jul/17 Updated: 29/Aug/18 Resolved: 29/Aug/18 |
|
| Status: | Done |
| Project: | Instrument control development |
| Component/s: | None |
| Affects Version/s: | None |
| Fix Version/s: | None |
| Type: | Task | Priority: | Minor |
| Reporter: | cloomis | Assignee: | arnaud.lefur |
| Resolution: | Done | Votes: | 0 |
| Labels: | SM1 | ||
| Remaining Estimate: | Not Specified | ||
| Time Spent: | Not Specified | ||
| Original Estimate: | Not Specified | ||
| Epic Link: | SM1 Phase Three |
| Description |
|
Data processing needs to know the dark time of an exposure as well as the exposure time. In most cases this is essentially the same, but if we ever pause exposures the calling sequencer will need to tell the ccdActor what the readStart - wipeEnd time is. The ccdActor's readout command now accepts an optional darktime=S argument. If not present it adds the expected shutter move time except for biases and darks. So there is no rush on this. |
| Comments |
| Comment by fmadec [ 17/Aug/17 ] |
|
We tried this version and got an error: 09:26:39.123731 RtdSM_client.pfs.spsait 235 ccd_r1 f text="command failed: TypeError(\"readout() got an unexpected keyword argument 'darkTime'\",) at /home/pfs/mhs/products/Linux64/ics_ccdActor/1.2.1/lib/python/ccdActor/Commands/exposure.py:132" |
| Comment by arnaud.lefur [ 17/Aug/17 ] |
|
It appears that I forgot to install ics_xcu_fpga:70.3.1 which include darkTime. |
| Comment by arnaud.lefur [ 06/Sep/17 ] |
|
There is still a bug, I need cloomis help on that one. |
| Comment by arnaud.lefur [ 29/Aug/18 ] |
|
merged in 258fb16 |