[INSTRM-1531] comments on a recent PFSC file Created: 25/Feb/22  Updated: 29/May/23

Status: Open
Project: Instrument control development
Component/s: None
Affects Version/s: None
Fix Version/s: None

Type: Task Priority: Normal
Reporter: monodera Assignee: cloomis
Resolution: Unresolved Votes: 0
Labels: EngRun, FITS
Remaining Estimate: Not Specified
Time Spent: Not Specified
Original Estimate: Not Specified

Issue Links:
Relates
relates to INSTRM-1444 Issues in PFSA files (based on PFSA06... Done

 Description   

FITS committee looked at PFSC06928100.fits and found a few minor issues. Some of comments in INSTRM-1444 may be also relevant.

  • Include queue-related keywords as discussed for PFSA files.
  • fomatting for float values need to be checked as pointed out for PFSA files.
  • DET-TMP : no value is provided
  • OBS-MOD is set as 'SPEC_ENG', but it can be 'IMAG_???'?
  • TELFOCUS is set as 'P_OPT2', but it can be 'CS_OPT'?
  • FOC-POS is set as 'PRIME', but it can be 'Cassegrain'?
  • ADC-TYPE need to be confirmed if 'IN' is preferred.
  • BLANK is set as 32767, but is it correct?


 Comments   
Comment by yuki.moritani [ 29/May/23 ]

Looking a FITS image during the last run, the following header cards are missing to start archiving to STARS.

  • DATA-TYP 
  • EXP-ID (PFSE00{visit:06d})
  • FRAMEID 
  • WCS-ORG (PFS pfs_utils) 
  • FILTER01  (It should be fixed as "BP635-58")
  • ADC-END (INSTRM-1871)
Generated at Sat Feb 10 16:36:33 JST 2024 using Jira 8.3.4#803005-sha1:1f96e09b3c60279a408a2ae47be3c745f571388b.