[INSTRM-1500] Fall back to using cobra centers when no cobra_target info available. Created: 13/Jan/22  Updated: 17/Feb/22  Resolved: 17/Feb/22

Status: Done
Project: Instrument control development
Component/s: ics_mcsActor
Affects Version/s: None
Fix Version/s: None

Type: Task Priority: Normal
Reporter: cloomis Assignee: chyan
Resolution: Done Votes: 0
Labels: EngRun
Remaining Estimate: Not Specified
Time Spent: Not Specified
Original Estimate: Not Specified

Story Points: 2
Sprint: PreEngRun05 B

 Description   

There are times when we want to take an MCS exposure and get fiber matches, but without knowing where the cobras are expected to be – there is no

{cobra_target}

information from the fpsActor. In that case populate the expected positions for the matching routines with the cobra centers.

Basically,

{mcs expose}

should assign fiber matches, but not fabricate opdb table rows (like for cobra_target) which it has no business touching.



 Comments   
Comment by chyan [ 17/Feb/22 ]

The actual implementation is in MCS. A function is implemented.