[INSTRM-1046] duplicate lamp-timed exposures are mis-sequenced Created: 07/Aug/20  Updated: 11/Aug/20  Resolved: 11/Aug/20

Status: Won't Fix
Project: Instrument control development
Component/s: ics_iicActor
Affects Version/s: None
Fix Version/s: None

Type: Bug Priority: Normal
Reporter: cloomis Assignee: cloomis
Resolution: Won't Fix Votes: 0
Labels: None
Remaining Estimate: Not Specified
Time Spent: Not Specified
Original Estimate: Not Specified


 Description   

sps.TimedArc and .TimedFlat append the dcb prepare commands to the sequence .head list, but the .expose() method appends to the regular sequence list. So all the dcb prepare commands happen before any of the exposures, and later exposures have no prepared lamps.

Obviously, add dcb prepare commands to the main command sequence.



 Comments   
Comment by cloomis [ 11/Aug/20 ]

Fixed in INSTRM-1048