Uploaded image for project: 'DRP 2-D Pipeline'
  1. DRP 2-D Pipeline
  2. PIPE2D-307

Arc wavelength calibration is inaccurate for at least one fiber

    XMLWordPrintable

    Details

    • Type: Story
    • Status: Done (View Workflow)
    • Priority: Normal
    • Resolution: Done
    • Affects Version/s: None
    • Fix Version/s: None
    • Component/s: None
    • Labels:
      None

      Description

      sogo.mineo reports:

      I plot pfsArm of Ne arc (visit=8927) together with the lines listed on ArCdHgKrNeXe.txt. The two do not match.

      This appears to me to be what is identified as fiberId=6:

      reduceArc.py ~/pfs/pipe2d-297/INTEGRATION/ --calib=$HOME/pfs/pipe2d-297/INTEGRATION/CALIB/ --rerun test1/arc --id visit=5830
      [...]
      reduceArc.calibrateWavelengths INFO: FiberId    6, rms -0.000pix (3.908pix for reserved points)
      

      Increasing the search radius (-c identifyLines.searchRadius=7 identifyLines.maxDistance=5.0) solves this, but may create different problems. cloomis has a better DetectorMap that should help.

        Attachments

          Activity

            People

            • Assignee:
              price price
              Reporter:
              price price
            • Votes:
              0 Vote for this issue
              Watchers:
              1 Start watching this issue

              Dates

              • Created:
                Updated:
                Resolved: