Uploaded image for project: 'DRP 2-D Pipeline'
  1. DRP 2-D Pipeline
  2. PIPE2D-1298

August 31st Weekly run feedback

    XMLWordPrintable

    Details

    • Type: Bug
    • Status: Open (View Workflow)
    • Priority: Normal
    • Resolution: Unresolved
    • Affects Version/s: None
    • Fix Version/s: None
    • Component/s: None
    • Labels:
      None

      Description

      I had a quick look at the results of the weekly run dated August 31st (2D version 2023.35).

      the results are globally OK (the object type selection works fine for example. The success rate in redshift measurement is only about 70%, dur to unmasked spikes (see below). As well some individual spectra show some peculiar issues :

      NIR arm flux calibration

      Red arm flux calibration

      There are some remaining spikes which are nor flagged nor masked (producing most of the redshift measurement errors)

      and in this spectrum there is a huge gap at the R/N interface (or close to)

       