      Description

      The getVisit command which failed this morning failed because the visit host was unreachable, and it returned in a few seconds. But iic reported that the failure was a 10s timeout. Would be nice to see the distinction instead of just blaming gen2.

      2025-05-21 20:57:49.660Z cmds             20 Actor.py:525 new cmd: getVisit caller=iic
      2025-05-21 20:57:55.813Z cmds             20 CommandLink.py:122 > 2 6609 f text="command failed: CamInterfaceError(remoteObjectError('Method call names(g2ins1.sum.subaru.nao.ac.jp).getInfo failed to g2ins1.sum.subaru.nao.ac.jp:7075: [Errno 113] No route to host')) in getFrames() at /software/mhs/products/Linux64/ics_gen2Actor/1.5.18/g2cam/g2cam/Instrument.py:880"
      