Uploaded image for project: 'Instrument control development'
  1. Instrument control development
  2. INSTRM-2147

Update boresignt in transform.py after MCS realignment

    XMLWordPrintable

    Details

    • Sprint:
      PreEngRun15Mar

      Description

      MCS camera assembly was re-aligned in January 2024 after an accident at the instrument exchange.  Since the spots moved on MCE camera (by ~25pix in camera y-axis), the boresight needs to be updated. (Without update, measured FF position as well as fiber home position is shifted due to distortion.)

      New bore sight at zenith is (4447.20, 2835.14)