Uploaded image for project: 'Instrument control development'
  1. Instrument control development
  2. INSTRM-1704

Current PFI XML contains incorrect L1 lengths

    XMLWordPrintable

    Details

    • Type: Task
    • Status: Won't Fix (View Workflow)
    • Priority: Normal
    • Resolution: Won't Fix
    • Component/s: None
    • Labels:
    • Story Points:
      1
    • Sprint:
      preEngRun07Sep

      Description

      As mentioned in INSTRM-1695, there are L1 length errors in the latest PFI XML file, https://github.com/Subaru-PFS/pfs_instdata/blob/master/data/pfi/modules/ALL/ALL_final_20220620_mm.xml:

      On 14. Sep 2022, at 16:14, Javier Gracia Carpio <jgracia@mpe.mpg.de> wrote:

      I had a quick look at the calibration product that we are supposed to use and it
      contains 4 cobras with wrong L1 link lengths (should be less than 3mm).
      These are their ids:

      L1 = [141.01257827, 292.38620107, 345.00520847, 638.06690293]
      moduleIds=[13, 23, 27, 27]
      positionerIds=[54, 49, 12, 57]
      serialIds= [1138, 2002, 1075, 3058]

      Please correct these, and any additional errors identified.

        Attachments

          Issue Links

            Activity

              People

              • Assignee:
                chyan chyan
                Reporter:
                hassan hassan
              • Votes:
                0 Vote for this issue
                Watchers:
                6 Start watching this issue

                Dates

                • Created:
                  Updated:
                  Resolved: