Ensure that hexapod moves always move _up_ to final position.

    XMLWordPrintable

    Details

    • Story Points:
      4
    • Sprint:
      SM1PD-2020 G2, SM1PD-2020 H

      Description

      Can the hexapod driving code always ensure that the slit moves up to the final position? I.e. if the target position is below the starting position, the hexapod should be moved past/below the target position first. Or maybe moves should always go past/down, then back?

      This would at least make moves consistent w.r.t. gravity.